Feature:
-Multiple functions, a total of 24 working modes. The maximum control current of the relay is 20A.
-Multiple supply voltages are optional: DC5V, DC 12V, DC24V
-The output terminal is isolated from the circuit by a relay, which can control low‑voltage electrical appliances, direct current, etc., and can also control 220V lines.
-To meet various testing and automatic control applications, the delay time is adjustable from 0.01 second to 999 minutes.
-Built to meet standard specification, strictly follow factory quality control.
Specification:
Optional Supply Voltage: DC5V, DC12V, DC24V
Maximum Relay Control Current: 20A
Button setting description: Power on display ''— — — —'' means to enter standby state
Press
K1 for the first time (it takes more than 1 second to be effective to
prevent false triggering) Display: P -11: K2 adjusts the main mode, K3 and K4
are adjustment function
Press the second time K1, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjust the decimal point (time unit)
Pressing the third K1, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit)
Pressing K1 for the fourth time, "— — — —" means to enter standby mode.
Press K4 in standby mode to permanently turn off/on the display and switch the low power mode.
Operating Mode:
P-11: Jog (give the signal relay, the signal disappears and the relay stops)
P-12: Self-locking (send a signal relay to pull in, then give a signal relay to stop)
P-13: Give the signal, the relay will stop automatically for A seconds; the trigger will be invalid during the delay.
P-14: Give signal, relay will stop automatically for A seconds; trigger re-time during delay
P-15: Give the signal, the relay will stop automatically for A seconds; trigger the superimposed timing during the delay.
P-16: Give signal, relay will stop automatically for A seconds; trigger reset during delay
P-17:
Give the signal, the relay is closed, the input signal is disconnected,
the power is turned off after A seconds, and the signal is kept output
again during the delay.
P-18: With power-on, the relay will immediately pull in, and pull off after a delay of A seconds
P-21: Give the signal, after a delay of A seconds, the relay pulls in
P-22: Give the signal, after more than A seconds, the relay pulls in, the signal disappears, the relay stops.
P-23: After the signal disappears for more than A seconds, the relay pulls in, the signal disappears, and the relay stops.
P-24:
There is a signal. After more than A seconds, the relay is closed. When
the signal disappears for more than A seconds, the relay stops.
P-25: There is a signal after more than A seconds, the relay is closed, and after a signal exceeds A seconds, the relay stops.
P-26:
There is a signal. The relay stops after A seconds of suction, and the
signal disappears. The relay stops again after A seconds.
P-27:
The pulse signal is detected and the relay stops; if there is no pulse
signal, the relay delays for A seconds; (the signal is continuous or the
signal disappears as no pulse signal)
P-28: After power-on, after a delay of A seconds, the relay pulls in until the power is turned off.
P-31: After power-on, the relay is closed for A seconds, disconnected for B seconds, infinite loop;
P-32: Signal, start P-31 infinite loop; signal disappears, terminate loop
P-33: Give a signal, start P-31 infinite loop; give another signal to terminate the loop
P-34: After power-on, after a delay of A seconds, the relay pulls in and closes after B seconds.
P-35: There is a signal. After a delay of A seconds, the relay pulls in and closes after B seconds.
P-36:
There is a signal. After more than A seconds, the relay is closed, the B
is stopped after B seconds, the signal disappears, and the timing is
cleared.
P-37:
There is a signal, the relay will stop automatically for A seconds, and
then stop for 24 seconds. The signal trigger is invalid during A+B
time.
P-38:
There is a signal, the relay will stop automatically for A seconds,
stop and re-time for B seconds, and then automatically close for A
seconds.
Decimal time unit description:
X.XX decimal point in hundred, timing range: 0.01 seconds to 9.99 seconds
XX.X decimal point in ten, timing range: 0.1 seconds to 99.9 seconds
XXX has no decimal point, timing range: 1 second ~ 999 seconds
XXX. The decimal point is in one place, the time range is from 1 minute to 999 minutes.
Package includes: